Common Faults in Solar Inverters: How to Identify, Prevent, and Resolve Them
Solar inverters are the backbone of any photovoltaic (PV) system, converting DC power from panels into AC power for use in homes, industries, or the grid. Despite their critical role, inverters are also the most failure-prone component in a solar system. Understanding common inverter faults is essential for maximizing uptime, protecting equipment, and ensuring energy yield.
1. Understanding Solar Inverter Fault Categories
Faults in solar inverters typically fall into the following categories:
A. DC-Side (Input) Faults
-
Reverse Polarity: Caused by incorrect wiring; may damage the input circuit or blow fuses.
-
Ground Faults: Often due to insulation failure or moisture ingress; leads to inverter tripping and fire hazards.
-
Open Circuit: Occurs when a string is disconnected; results in zero power generation from that string.
-
Short Circuit: Internal module failures or wiring faults; inverter protection usually kicks in to shut it down.
-
Overvoltage/ Undervoltage: Mismatched string voltage outside the inverter’s threshold can cause automatic shutdown or low efficiency.
B. AC-Side (Output) Faults
-
Grid Faults: Fluctuations, outages, or frequency variations trigger inverter shutdown.
-
Overcurrent/ Phase Imbalance: Caused by faulty load or grid-side wiring; can damage the inverter.
-
Back-feed Faults: When the grid feeds power back to the inverter, possibly causing sync errors or damage.
C. Inverter Internal Faults
-
Component Failure: Overheating, capacitor failure, or internal circuit breakdowns can cause total or partial shutdown.
-
Firmware/Software Errors: These prevent communication, grid synchronisation, or protection sequences from executing.
-
Over-temperature: If cooling fails, the inverter may throttle or shut down to protect itself.
D. Communication & Monitoring Faults
-
Loss of Connectivity: Faulty RS-485/Ethernet/Wi-Fi connections impact real-time monitoring.
-
Incorrect Fault Codes: Software glitches or outdated firmware can lead to false alarms or delayed responses.
2. Indicators of Inverter Faults
Watch for:
-
Blinking LEDs or fault lights
-
Error/fault codes on the display or monitoring system
-
Abnormal voltage or frequency levels
-
Drop in daily or instantaneous energy yield
-
Audible alarms or shutdowns
3. Diagnostic Strategies
-
SCADA or Monitoring Software: Use it for real-time fault alerts and performance logs.
-
Onsite Visual Inspections: Check for physical damage, loose wiring, and burnt smells.
-
Thermal Imaging: Detect overheating components or hot-spots.
-
Multi-meter/IV Curve Tracing: Pinpoint DC-side faults like open or short circuits.
4. Preventive Measures
-
Schedule regular inverter servicing (quarterly or bi-annually)
-
Maintain proper cable terminations and cleanliness
-
Ensure proper ventilation and shading protection for inverters
-
Update firmware regularly from the OEM
-
Use high-quality surge protection and earthing systems
5. When to Replace the Inverter
If your inverter:
-
Experiences frequent shutdowns despite troubleshooting
-
Shows signs of irreversible hardware damage
-
Is out of warranty and spare parts are unavailable
-
Consistently under-performs even after re-calibration
It’s likely time to consider a replacement.
Conclusion
Solar inverter faults are inevitable, but with robust monitoring, proactive maintenance, and accurate diagnostics, their impact can be minimised. Inverter health directly correlates to plant profitability and reliability—don’t ignore the warning signs.